ATLOSON PRODUCT RANGE
Find the right thermal system.
Select Your Model

EMBER Cooktop
SL451–4.5 kW · Diesel · 12V · Installation Kit
SKU: ATL-EMB-SL45In Stock
About the EMBER SL45
The EMBER SL45 is a diesel-powered pull-out cooktop for stationary outdoor cooking. Its sliding installation provides a compact stowed position and an accessible cooking surface when fully extended.
Deploy and lock both slide stages before use. Stop the appliance and allow the shutdown and cooling cycle to finish before retracting it.
Key Benefits
- Electrical system: 12 V DC
- Max startup current: 8–10 A
- Average current: 0.32–0.40 A
- Heat range: 1–4.5 kW
Applications
Cooking and/or heating according to the selected EMBER model and its published functions.
Specifications
- Model
- EMBER SL45
- Output
- 1–4.5 kW
- Fuel
- Diesel
- Voltage
- 12V
- Electrical system
- 12 V DC
- Max startup current
- 8–10 A
- Average current
- 0.32–0.40 A
- Heat range
- 1–4.5 kW
- Fuel consumption
- 100–450 mL/h
- Ambient range
- −40 to +40 °C (catalog value)
- Altitude
- ≤5,000 m (catalog value)
- Weight
- 11.5 kg
- Dimensions
- 550 × 411 × 183 mm
- Operating voltage
- 12V
- Application
- Outdoor cooking only
- Startup current
- 8–10 A
- Mounting
- Horizontal, within 5°
- Deployment
- Two-stage sliding mechanism; lock before use
- Selected SKU
- ATL-EMB-SL45
Reference information is subject to engineering review. Confirm the final specifications for your installation.
What’s included
- Package
- Complete installation kit
- Controller
- To confirm
- Accessories
- No additional accessories selected
Complete heater kit as identified by this SKU. The controller follows the product designation. Confirm the ATLOSON packing list: compatible accessories and lists for other configurations do not establish the contents of this kit.
Delivery & warranty
Delivery time and charges depend on the destination, available stock and selected options. Contact ATLOSON for an estimate.
Contact ATLOSON to confirm warranty coverage and conditions for this configuration. Burners are excluded from warranty coverage.
Contact technical supportDocuments
Complete manual downloads
- Download EMBER SL45 Installation & Operation Manual – English PDFV5 · 6 pages · English
- Télécharger le manuel d’installation et d’utilisation EMBER SL45 – Français PDFV5 · 6 pages · Français
- Descargar el manual de instalación y funcionamiento EMBER SL45 – Español PDFV5 · 6 pages · Español
- EMBER SL45 Installations- und Bedienungsanleitung herunterladen – Deutsch PDFV5 · 6 pages · Deutsch
- Скачать руководство по установке и эксплуатации EMBER SL45 – Русский PDFV5 · 7 pages · Русский
Installation
On receipt, record the SKU, serial number, voltage, fuel and controller revision, and photograph the nameplate. Check the heater, harness, controller, pump, pipes, seals and fasteners actually supplied. Prepare maintenance access, protected routing, a suitable electrical supply and combustion exhaust outside the occupied space.
Check stability, clearances and whether the variant is for indoor or outdoor use. Distinguish cooking-only, combined heating and portable cooktops; provide the specified intake and exhaust.
Use the mounting points and clearances specified for the delivered unit. Mount horizontally within 5° and keep access to the fuel, wiring and slide mechanism.
Use outdoors while stationary. Confirm the fuel circuit, wiring and controller revision with a qualified installer. Do not mix the dimensions or mounting instructions for a recessed/lifting stove with this pull-out model.
Commissioning checks
Check mounts, connections, protective devices and seals before starting. Bleed or prime only as instructed in the manual. Measure voltage at the appliance during startup; check stable operation, temperatures and unusual smoke or leaks. Test controlled shutdown and completion of cooling, recording conditions, measurements and serial number.
Operation
Pull out and lock both slide stages before starting. Keep the cooking surface clear and do not cover an operating appliance.
Follow the supplied controller instructions. Complete shutdown and cooling before retracting, moving or refuelling.
Maintenance
Inspect fuel-line leaks, wiring connections, corrosion and slide locking. Have installation and service work performed by qualified personnel.
Troubleshooting & support
Record the exact error code, a screen photograph, voltage at rest and startup, symptoms and circumstances. Check supply/connectors, fuel, intake and exhaust; on coolant systems, also check filling, bleeding and circulation. Use the installed controller’s code table; do not interchange OLED, LCD and AT1192 codes. Stop for leaks, odours or overheating and obtain professional diagnosis before replacing electronics.
Before you buy
- Required use and output
- Voltage and fuel
- Available installation space
- Combustion intake and exhaust
- Compatible controller and required installation components
- Exact packing list
Select for actual use, heat losses, climate and installation architecture. Nominal output alone does not establish compatibility or autonomy.
Contact us about your application →Questions & answers
What does reference ATL-EMB-SL45 identify?
EMBER SL45. Complete installation kit; fuel: Diesel; voltage: 12V. Cooking and/or heating according to the selected EMBER model and its published functions.
What should I check for EMBER SL45?
Part reference and mounting interface. Confirm the exact delivered model and configuration before ordering.