EMBER SL45 Installation & Operation Manual
EMBER SL45 · English · 6 PDF pages
Supplied V5 edition, marked draft for approval. Unresolved values remain ‘To be confirmed’. Check the delivered unit’s SKU, fuel, voltage, serial number and controller revision; references are not proof of compatibility.
Current ATLOSON warranty excludes burners. Original documents may describe earlier terms; consult the current warranty on the product page.
Complete manual downloads
- Download EMBER SL45 Installation & Operation Manual – English PDFV5 · 6 pages · English
- Télécharger le manuel d’installation et d’utilisation EMBER SL45 – Français PDFV5 · 6 pages · Français
- Descargar el manual de instalación y funcionamiento EMBER SL45 – Español PDFV5 · 6 pages · Español
- EMBER SL45 Installations- und Bedienungsanleitung herunterladen – Deutsch PDFV5 · 6 pages · Deutsch
- Скачать руководство по установке и эксплуатации EMBER SL45 – Русский PDFV5 · 7 pages · Русский
Current catalogue configurations
These links show the current catalogue identifiers. Reference SKUs in the supplied V5 manual may differ; confirm the delivered unit before installation or ordering.
| Configuration | Power | Voltage | Fuel |
|---|---|---|---|
| ATL-EMB-SL45 · Complete system | 1–4.5 kW | 12V | Diesel |
01 Identification, safety and use
This manual accompanies model EMBER SL45. Record SKU, serial number, voltage, fuel and revision before installation. Accessories, functions and protective devices depend on the supplied variant.
Cooking in a mobile installation according to version; air heating only for H versions. P45 and SL45: outdoor cooking, stationary, clear and stable unit.
| SKU | Fuel | Voltage |
|---|---|---|
| ATL-EMB-SL45 | Diesel | 12V |
Carbon monoxide: combustion gases must remain outside occupied spaces. Do not operate in a garage or other enclosed location. Keep intakes and flue outlets clear, especially after snow, mud or travel.
Fuel smell, abnormal smoke, leakage or a CO alarm: stop use, move occupants away and have the installation inspected. Do not restart to conceal a fault. Contact emergency services if there is immediate danger.
Fire and burns: keep combustible materials away from the appliance, hot ducts and exhaust. Do not use the service compartment for storage. Allow cooling before inspection and keep children away from hot surfaces.
Power: use the nameplate voltage. Never increase a fuse rating or bypass protection. For a normal stop, allow the controlled cooling cycle to finish before disconnecting power.
Stop before refuelling. Fuel, combustion, gas and mains work require a qualified professional. Install and maintain a CO detector suitable for the application according to its own instructions.
Cooking appliance: operate while stationary and supervised, with appropriate cookware and a clear surface. Do not heat empty cookware. Do not assign heating mode to C18/C22 without validation; the shop explicitly lists it for C18H/C22H. For P45/SL45, confirm stability, moving-section locking and exhaust discharge before use.
02 Variant specifications
| Common specification | Value |
|---|---|
| Fuel | Diesel |
| Operating voltage | 12V |
| Heat output class | 1-4.5 kW |
| Electrical supply | 12 V DC |
| Maximum starting current | 8-10 A |
| Average current | 0.32-0.40 A |
| Heat output range | 1-4.5 kW |
| Fuel consumption | 100-450 mL/h |
| Ambient temperature | -40 to +40 °C (catalogue value) |
| Altitude | ≤5,000 m (catalogue value) |
| Weight | 11.5 kg |
| Dimensions | 550 × 411 × 183 mm |
For unpublished values, use the supplied variant's nameplate and data sheet: starting current, fastening torque, pressure, pump flow and protection devices cannot be inferred from power.
03 Recommended applications and output selection
Select according to insulation, outdoor temperature, heated volume and air exchange. For domestic water: water demand, pressure and frost protection. Engine displacement and engine coolant volume are not applicable to this unit.
04 Assembly identification
Diesel Outdoor cooktop Cookware
Flame / gas: clear outdoor area
Functional identification diagram. A revision-specific internal drawing must accompany any disassembly work.
05 Step-by-step installation
STEP 1 - Check the positioning
For C18/C22 and H versions, position the template for the actual supplied single or double zone. Maintain ventilation and clearances around and beneath the unit. P45/SL45: install outdoors on a stable support.
STEP 2 - Mount the unit
Use the support and fastening points for the version. On SL45 check leveling, slide travel and locking; no use while moving.
STEP 3 - Connect fuel and combustion circuits
Secure the pump, filter and lines without air pockets. Keep fuel away from the hot path. C18/C22: intake and exhaust remain separated from occupied space.
ACTION DETAIL - schematic
Insert both tubes until they meet.
Detail: no air pocket between tubes.
STEP 4 - Connect the harness
Identify power, controller, pump and sensors before connection. Keep the harness and protection devices specific to the cooker. An air-heater controller is not a replacement for a cooking controller.
STEP 5 - Test the modes
Supervise cooking with suitable cookware. On H versions only, check warm-air mode and the specified lid position. Stop and wait for cooling before cleaning or storage.
06 Electrical connections
DC battery Fuse holder ECU / unit SL45
+ protected near the battery; dedicated - return
Compatible controller Signal harness
Schematic. Pins, rating and voltage: use the supplied harness.
Maintain power during cooling. Normal shutdown uses the controller; do not install a switch that interrupts the cycle. Protect cables and connections against water, abrasion and heat.
07 Initial commissioning
| Check | Result to verify |
|---|---|
| Rating plate and controller | SKU, voltage, fuel and connectors match |
| Mounting | Mountings, clearances, ducts and outlets checked |
| Fluid circuit | Filled and bled; no leaks |
| Supply under load | Voltage measured during starting |
| Complete cycle | Ignition, operation, setpoint and shutdown/cooling tested |
| Delivery | Rating-plate photo, measurements, date and installer recorded |
08 Operation and controls
Use the supplied controller for starting, adjustment and stopping. Cooking remains supervised. Heating functions are only for variants designed for that mode.
| Situation | Action |
|---|---|
| Before cooking | Check stability, power, fuel and absence of flammable material near the unit. Use a stable vessel suitable for the cooking surface. Keep air intakes and exhaust routes clear. |
| Cooking and heating | Adjust power gradually and supervise cooking. C18/C22 are cooking versions; warm-air mode is only for C18H/C22H configured for it. Do not cover a hot surface to simulate heating mode. |
| Outdoor versions | P45 and SL45: use outdoors, not in a moving vehicle. Extend and secure the SL45 mechanism before starting; prevent accidental retraction during combustion. Stop before refueling. |
| After cooking | Stop with the controller, wait for shutdown and cooling, then clean using a method suitable for the surface. Do not spray water onto electronics or the burner. Retract a sliding version only after complete cooling. |
09 Maintenance and winterization
| When | Work |
|---|---|
| Before use | Check fuel, battery, ducts, outlets, connections and absence of leaks. |
| After transport | Inspect mountings, cables, ducts and exposed components. |
| Before the season | Supervised test; full inspection of combustion and protective devices. |
| After repair | Suitable seals, leak test, complete cycle and measurements recorded. |
Before use and after travel, inspect ducts, supports, openings, fuel lines and accessible connections. Once cool, remove external debris without directing water into the intake or flue.
Before the season and after storage, have the installation, battery, protection, tightness and combustion checked. Hour-based intervals, exercise-run duration and component life remain to be confirmed for the exact model and revision.
The user may keep access clear and clean cold surfaces using material-appropriate methods. Burner, exchanger, pump, sensor and ECU removal is qualified service work. Do not adjust fuel delivery or thermal protection.
After repair, require leak checks and a full cycle. Record date, hours, symptom, code, part SKUs and technician. Confirm applicable warranty terms with ATLOSON; other warranty policies are not transferred.
10 Troubleshooting and fault codes
| Symptom | Action |
|---|---|
| Display off | Check the permitted power supply, visible connection and identified protection device; a fuse that blows again requires professional diagnosis. |
| No ignition / flameout | Record the code and check fuel level and visible obstructions. Do not repeat starting or priming attempts; have fuel dosing and combustion checked. |
| Overheating / low heat output | Keep air passages clear. On a coolant circuit, allow cooling before checking the level; have air bleeding, circulation and pump checked. Do not bypass the sensor. |
| Smoke / odor / leak | Stop using the system and have it inspected before returning it to service. Do not tighten or repair a hot pipe. |
| Communication / remote control | Record the message and version. Have harness and protocol confirmed. For GSM, check the module and network availability with the installer. |
Record the exact code before clearing it. Stop and allow cooling, check the power supply under load, then ducts and the fluid circuit. Correct the cause before a supervised test. A repeated fault requires workshop service.
For a code not described here, record the number, controller revision and circumstances; send them to ATLOSON support. Do not use a fault table from another type of unit.
11 Parts, kits and purchasing
Order by part number and variant. Drawing callouts are not SKUs. Check voltage, fuel and connector before replacement. A complete-system reference is not a maintenance kit.
ATLOSON parts
Records and support
Date / hours: __________________ Work / parts: __________________
Keep the invoice, SKU, serial number and history. For assistance, provide a nameplate photo, code and symptom. ATLOSON support