THERMAL SYSTEMS
POWERING A BETTER TOMORROW
ATLOSON › Manuals › ORCA UC5000ENGINEERED FOR EXTREME CONDITIONS
ATLOSON · V5 · English

ORCA UC5000 Installation & Operation Manual

ORCA UC5000 · English · 11 PDF pages

Supplied V5 edition, marked draft for approval. Unresolved values remain ‘To be confirmed’. Check the delivered unit’s SKU, fuel, voltage, serial number and controller revision; references are not proof of compatibility.

Current ATLOSON warranty excludes burners. Original documents may describe earlier terms; consult the current warranty on the product page.

Complete manual downloads

Current catalogue configurations

These links show the current catalogue identifiers. Reference SKUs in the supplied V5 manual may differ; confirm the delivered unit before installation or ordering.

ORCA UC5000: power, voltage and fuel in the current catalogue
ConfigurationPowerVoltageFuel
ATL1005 · Complete system5 kW12VDiesel
ATL1006 · Complete system5 kW24VDiesel
ATL1007 · Complete system5 kW12VGasoline

01 Identification, safety and use

Source PDF pages: 2

This manual accompanies model ORCA UC5000. Record SKU, serial number, voltage, fuel and revision before installation. Accessories, functions and protective devices depend on the supplied variant.

Engine preheating and heating of a closed antifreeze circuit; cabin heating via a separate heat exchanger. No direct connection to drinking water.

01 Identification, safety and use
SKUFuelVoltage
ATL-ORC-UC50-D12Diesel12V
ATL-ORC-UC50-D24Diesel24V

Carbon monoxide: combustion gases must remain outside occupied spaces. Do not operate in a garage or other enclosed location. Keep intakes and flue outlets clear, especially after snow, mud or travel.

Fuel smell, abnormal smoke, leakage or a CO alarm: stop use, move occupants away and have the installation inspected. Do not restart to conceal a fault. Contact emergency services if there is immediate danger.

Fire and burns: keep combustible materials away from the appliance, hot ducts and exhaust. Do not use the service compartment for storage. Allow cooling before inspection and keep children away from hot surfaces.

Power: use the nameplate voltage. Never increase a fuse rating or bypass protection. For a normal stop, allow the controlled cooling cycle to finish before disconnecting power.

Stop before refuelling. Fuel, combustion, gas and mains work require a qualified professional. Install and maintain a CO detector suitable for the application according to its own instructions.

Coolant heating: the appliance belongs in an approved cooling loop and needs adequate circulation. Confirm flow direction, pump, bleeding, fluid compatibility, valves, flow rate and pressure. Never work on a hot or pressurised loop. Engine coolant is not drinking water.

02 Variant specifications

Source PDF pages: 2, 3
02 Variant specifications
Common specificationValue
FuelDiesel
Heat output class5 kW

Differences between variants

02 Variant specifications
SpecificationSKUValue
Operating voltageATL-ORC-UC50-D1212 V DC (10.5-16 V range)
Operating voltageATL-ORC-UC50-D2424 V DC
Heat outputATL-ORC-UC50-D122.4-5.0 kW
Heat outputATL-ORC-UC50-D245 kW class
Approximate outputATL-ORC-UC50-D12Up to 17,061 BTU/h
Approximate outputATL-ORC-UC50-D24Depending on variant
Fuel consumptionATL-ORC-UC50-D120.27-0.62 L/h
Electrical power during operationATL-ORC-UC50-D12Catalogue value: 14-29 W (catalogue range)
DimensionsATL-ORC-UC50-D12Catalogue value: 223 × 86 × 152 mm
WeightATL-ORC-UC50-D12Catalogue value: 2.6 kg
Temperature settingATL-ORC-UC50-D12Catalogue value: 5-35 °C
Temperature settingATL-ORC-UC50-D24Depending on variant
Altitude functionATL-ORC-UC50-D12Up to 5,000 m (catalogue value)
Altitude functionATL-ORC-UC50-D24Depending on variant
02 Variant specifications
SpecificationSKUValue
ControllerATL-ORC-UC50-D12Depending on variant
ControllerATL-ORC-UC50-D24Programmable digital controller
ApplicationATL-ORC-UC50-D12Depending on variant
ApplicationATL-ORC-UC50-D24Cooling circuit / antifreeze

For unpublished values, use the supplied variant's nameplate and data sheet: starting current, fastening torque, pressure, pump flow and protection devices cannot be inferred from power.

03 Recommended applications and output selection

Source PDF pages: 3
03 Recommended applications and output selection
Indicative engine displacement1,5 à 3 L
Coolant circuitRecord the vehicle's actual capacity and size for target temperature, available time, circulation and heat losses.

Engine-displacement ranges are selection guides. They do not establish a circuit-volume limit. Use the vehicle-specified antifreeze mixture and a suitable pump.

04 Functional section and UC5000 circuit

Source PDF pages: 3

Drawing callouts: identify components before service. A sectional view shows operation; it does not define a disassembly sequence. Check the unit revision before ordering any part.

05 Step-by-step installation

Source PDF pages: 4, 5

STEP 1 - Mount the heater

Provide an accessible rigid support. Identify coolant inlet and outlet on the unit and leave clearance for the burner, pump and connections.

STEP 2 - Create the hydraulic circuit

Connect to the closed antifreeze circuit. Follow circulation direction and avoid restrictions and high points trapping air. Install the pump suitable for the circuit; separate engine coolant from drinking water.

Unit orientation Closed coolant circuit

STEP 3 - Fill and bleed

With the engine cold, fill with the vehicle-specified coolant. Open the necessary valves, bleed the heater and pump, then check level and leak tightness. Never start dry.

ACTION DETAIL - schematic

Insert both tubes until they meet.

Detail: no air pocket between tubes.

STEP 4 - Connect combustion circuits

Install combustion intake and exhaust outside the cabin. For UC5000/UC9000 use the matched metering pump. For larger units follow the supplied burner's architecture: do not replace the circuit with a small metering pump.

Heater and pump position Metering pump

STEP 5 - Check electrical supply and heating

Test power under load and circulation. Measure supply/return temperatures. Check the cabin-fan control if fitted. Complete a full shutdown and recheck the level when cold.

06 Electrical connections

Source PDF pages: 6

DC battery Fuse holder ECU / unit UC5000

+ protected near the battery; dedicated - return

Compatible controller Signal harness

Schematic. Pins, rating and voltage: use the supplied harness.

Maintain power during cooling. Normal shutdown uses the controller; do not install a switch that interrupts the cycle. Protect cables and connections against water, abrasion and heat.

Circuit detail for the illustrated family. Drawing labels identify components; check connectors, voltage and options on the supplied harness. A mains connection cannot be inferred from nominal power alone.

07 Initial commissioning

Source PDF pages: 6
07 Initial commissioning
CheckResult to verify
Rating plate and controllerSKU, voltage, fuel and connectors match
MountingMountings, clearances, ducts and outlets checked
Fluid circuitFilled and bled; no leaks
Supply under loadVoltage measured during starting
Complete cycleIgnition, operation, setpoint and shutdown/cooling tested
DeliveryRating-plate photo, measurements, date and installer recorded

08 Operation and controls

Source PDF pages: 7

The coolant heating setpoint differs from ambient temperature. Set the duration and program on the compatible circuit controller; check circulation and battery charge before automatic start.

08 Operation and controls
SituationAction
Before startingWhen cold, check level and antifreeze protection. Ensure required valves are open and the circuit is filled and bled. Do not start with an empty or frozen circuit. Never open a hot pressurized circuit cap.
Engine preheatingProgram time only after an initial supervised test. Start with the correct coolant-heater controller. Displayed room temperature does not necessarily represent the coolant setpoint. Check circulation, leaks and gradual temperature rise.
Cabin heatingIf a heat exchanger and vehicle fan controller are installed, check their operation separately. Cabin heating consumes some heat output and battery power; allow a longer preheating time than with coolant alone.
Shutdown / circulation faultStop normally with the controller; maintain power during purging and cooling. If overheating occurs or hoses remain abnormally cold, allow cooling and have the level, air bleeding, valves, restrictions and pump checked before restarting.

09 Maintenance and winterization

Source PDF pages: 7
09 Maintenance and winterization
WhenWork
Before useCheck fuel, battery, ducts, outlets, connections and absence of leaks.
After transportInspect mountings, cables, ducts and exposed components.
Before the seasonSupervised test; full inspection of combustion and protective devices.
Engine circuitCheck cold level, antifreeze protection, bleeding and circulation.
After repairSuitable seals, leak test, complete cycle and measurements recorded.

Before use and after travel, inspect ducts, supports, openings, fuel lines and accessible connections. Once cool, remove external debris without directing water into the intake or flue.

Before the season and after storage, have the installation, battery, protection, tightness and combustion checked. Hour-based intervals, exercise-run duration and component life remain to be confirmed for the exact model and revision.

The user may keep access clear and clean cold surfaces using material-appropriate methods. Burner, exchanger, pump, sensor and ECU removal is qualified service work. Do not adjust fuel delivery or thermal protection.

After repair, require leak checks and a full cycle. Record date, hours, symptom, code, part SKUs and technician. Confirm applicable warranty terms with ATLOSON; other warranty policies are not transferred.

10 Troubleshooting and fault codes

Source PDF pages: 7
10 Troubleshooting and fault codes
SymptomAction
Display offCheck the permitted power supply, visible connection and identified protection device; a fuse that blows again requires professional diagnosis.
No ignition / flameoutRecord the code and check fuel level and visible obstructions. Do not repeat starting or priming attempts; have fuel dosing and combustion checked.
Overheating / low heat outputKeep air passages clear. On a coolant circuit, allow cooling before checking the level; have air bleeding, circulation and pump checked. Do not bypass the sensor.
Smoke / odor / leakStop using the system and have it inspected before returning it to service. Do not tighten or repair a hot pipe.
Communication / remote controlRecord the message and version. Have harness and protocol confirmed. For GSM, check the module and network availability with the installer.

Record the exact code before clearing it. Stop and allow cooling, check the power supply under load, then ducts and the fluid circuit. Correct the cause before a supervised test. A repeated fault requires workshop service.

11 Fault-code table - COOLANT

Source PDF pages: 8

Table for the controller/ECU of this family. The same number may have a different meaning on another revision.

11 Fault-code table - COOLANT
CodeMeaning
00 / B0Missing or lost communication
10Voltage too high
11Voltage too low
12 / 14 / 15 / 17Overheat or abnormal temperature by code
13 / 50Ignition failure / lockout by code
20 / 21 / 22Glow plug / circuit / version
30 / 31 / 32 / 33 / 84 / 85 / 86Blower: circuit, speed or start
38 / 39Auxiliary output/equipment circuit
41 / 42Circulation pump circuit
45 / 46Auxiliary output/equipment circuit
47 / 48Metering pump circuit
51 / 52 / 55 / 64 / 65Flame detection / sensor circuit
60 / 61 / 62 / 71 / 72Temperature sensor / circuit / limit
91 / 99ECU / memory
A9Abnormal power interruption
AA / AB / AC / AD / AE / AFSelf-test failure by circuit
D3Maintenance requested
E0 / E1 / E2 / E3Ignition / glow / flame monitoring
EEUnidentified fault

12 Parts, kits and purchasing

Source PDF pages: 8, 9, 10, 11

Order by part number and variant. Drawing callouts are not SKUs. Check voltage, fuel and connector before replacement. A complete-system reference is not a maintenance kit.

12 Parts, kits and purchasing
Reference / purchaseCatalogue description
AT10355Heater non-plateau to plateau adapter cable
AT10566Stainless Steel Fuel Tank 10L Gasoline Storage for Parking Heater
AT10567Stainless Steel Thru Hull Fitting, 22 mm, 90° Base, Angled Connector, Boltless
AT1121UC5000 - MAINTENANCE KIT 12V DIESEL
AT11212UC5000 - MAINTENANCE KIT 12V DIESEL
AT11212UC5000 - Heater Only 12v Diesel
AT1122UC5000 - Heater Only 24v Diesel
AT1123UC5000 - Heater Only 12v Gasoline
AT1125Coolant pump with support 12V
AT1126Coolant pump with support 24V
AT1127UC5000 - Flame tube GASOLINE
AT1128UC5000 - Flame tube DIESEL
AT1129Heat exchanger jacket (outer casing)
12 Parts, kits and purchasing
Reference / purchaseCatalogue description
AT1131Heat exchanger O-ring 74*3mm
AT1132UC5000 - ECU assembly 12V GASOLINE
AT1133UC5000 - ECU assembly 12V DIESEL
AT1134UC5000 - ECU assembly 24V DIESEL
AT1135Combustion blower motor assembly 12V
AT1136Combustion blower motor assembly 24V
AT1137Air blower assy cover with air intake port
AT1138Seal, flame tube and blower assembly
AT1139Seal, flame tube to heat exchanger 81.5*69*1mm
AT1140Coolant barb O-ring SAE#114 (13*2mm)
AT1141Heat exchanger top cover
AT1142Top cover for air blower assembly
AT1143Flame sensor
AT1144Glow plug lining
AT1145Glow plug lining O-ring 9*2mm
AT1146FUEL TANK 10, PLASTIK
AT1147Glow plug 12V
AT1148Glow plug 24V
AT1149Glow plug O-ring 8*1mm FPM
AT1150Glow plug connection with fuel intake tube
AT1151Glow plug connection O-ring 11*1mm FPM
AT1152Temperature and overheat sensor assy
AT1153O-ring for temperature and overheat sensors 7.5*2mm
AT1154Spring leaf for temperature and overheat sensors
AT1155Muffler
AT1156UC5000 - Wiring harness 12V
AT1157UC5000 - Wiring harness 24V
AT1158Fuel pump 12V
AT1159Fuel pump 24V
AT1160Fuel pump damper
AT1161Fuel pump support
AT1165Bolt M6×10mm
AT1166Nut M6
AT1167Flat washer 6mm*12mm
AT1168Split lock washer, M6
AT1169Fuel filter
AT1170Fuel line φ5×2.0mm L1m
AT1171Fuel line φ4mm×φ1.5mm L6m, clear
12 Parts, kits and purchasing
Reference / purchaseCatalogue description
AT1172Fuel line coupling 3.5*9.5*40mm
AT1173Fuel line coupling 4.1*10.5*40mm
AT1174Fuel line clamp φ8-10mm
AT1175Fuel line clamp φ9-11mm
AT1176Coolant hose φ17*26mm CR01-5A(EPDM)
AT1177Coolant hose clamp φ20-32mm
AT1178Coolant hose coupling φ20mm, L55mm
AT1179Coolant hose reducing coupling φ18*20mm, L60mm
AT1180Air inlet pipe 20.5 x 24mm x L900mm
AT1181Air inlet pipe strap
AT1182Air inlet pipe clamp φ16-25mm
AT1183Exhaust pipe
AT1184Exhaust pipe strap
AT1185Exhaust pipe clamp 24-28mm
AT1186Heater mounting bracket
AT1187Rubber shock absorbers 5*20*4mm
AT1188Self-drilling and self-tapping screw ST5.5×30
AT1189Fuel pickup tube
AT11914-port bypass valve
AT119101Air Intake Silencer
AT119102Elbow Connector, 90
AT119103Relay 12V
AT119104Relay 24V
AT119105Fuel Pump Connector
AT119106Fuse, 24V (15A)
AT119107Fuse, 12V (20A)
AT119108Fuse Base
AT119109Fuse Base 2
AT119110Encloruse Box kit
AT1192Digital control switch, GSM compatible
AT1193Check valve
AT15001Diagnostics USB Cable
ATL1005UC5000 Heater Kit, Coolant Heater, 5kw, 12v, Diesel, Controller LCD - BT
ATL1006UC5000 Heater Kit, Coolant Heater, 5kw, 24v, Diesel, Controller LCD - BT
ATL1007UC5000 Heater Kit, Coolant Heater, 5kw, 12v, Gasoline, Controller LCD - BT
ATM001006ORCA UC5000 Instruction Manual

Records and support

Date / hours: __________________ Work / parts: __________________

Keep the invoice, SKU, serial number and history. For assistance, provide a nameplate photo, code and symptom. ATLOSON support