ORCA UC9000 Installation & Operation Manual
ORCA UC9000 · English · 10 PDF pages
Supplied V5 edition, marked draft for approval. Unresolved values remain ‘To be confirmed’. Check the delivered unit’s SKU, fuel, voltage, serial number and controller revision; references are not proof of compatibility.
Current ATLOSON warranty excludes burners. Original documents may describe earlier terms; consult the current warranty on the product page.
Complete manual downloads
- Download ORCA UC9000 Installation & Operation Manual – English PDFV5 · 10 pages · English
- Télécharger le manuel d’installation et d’utilisation ORCA UC9000 – Français PDFV5 · 10 pages · Français
- Descargar el manual de instalación y funcionamiento ORCA UC9000 – Español PDFV5 · 10 pages · Español
- ORCA UC9000 Installations- und Bedienungsanleitung herunterladen – Deutsch PDFV5 · 10 pages · Deutsch
- Скачать руководство по установке и эксплуатации ORCA UC9000 – Русский PDFV5 · 10 pages · Русский
Current catalogue configurations
These links show the current catalogue identifiers. Reference SKUs in the supplied V5 manual may differ; confirm the delivered unit before installation or ordering.
| Configuration | Power | Voltage | Fuel |
|---|---|---|---|
| ATL9001 · Complete system | 9 kW | 12V | Diesel |
| ATL9003 · Complete system | 9 kW | 24V | Diesel |
01 Identification, safety and use
This manual accompanies model ORCA UC9000. Record SKU, serial number, voltage, fuel and revision before installation. Accessories, functions and protective devices depend on the supplied variant.
Engine preheating and heating of a closed antifreeze circuit; cabin heating via a separate heat exchanger. No direct connection to drinking water.
| SKU | Fuel | Voltage |
|---|---|---|
| ATL-ORC-UC90-D12 | Diesel | 12V |
| ATL-ORC-UC90-D24 | Diesel | 24V |
Carbon monoxide: combustion gases must remain outside occupied spaces. Do not operate in a garage or other enclosed location. Keep intakes and flue outlets clear, especially after snow, mud or travel.
Fuel smell, abnormal smoke, leakage or a CO alarm: stop use, move occupants away and have the installation inspected. Do not restart to conceal a fault. Contact emergency services if there is immediate danger.
Fire and burns: keep combustible materials away from the appliance, hot ducts and exhaust. Do not use the service compartment for storage. Allow cooling before inspection and keep children away from hot surfaces.
Power: use the nameplate voltage. Never increase a fuse rating or bypass protection. For a normal stop, allow the controlled cooling cycle to finish before disconnecting power.
Stop before refuelling. Fuel, combustion, gas and mains work require a qualified professional. Install and maintain a CO detector suitable for the application according to its own instructions.
Coolant heating: the appliance belongs in an approved cooling loop and needs adequate circulation. Confirm flow direction, pump, bleeding, fluid compatibility, valves, flow rate and pressure. Never work on a hot or pressurised loop. Engine coolant is not drinking water.
02 Variant specifications
| Common specification | Value |
|---|---|
| Fuel | Diesel |
| Heat output class | 9 kW |
| Approximate output | Up to 31,050 BTU/h |
Differences between variants
| Specification | SKU | Value |
|---|---|---|
| Operating voltage | ATL-ORC-UC90-D12 | 12 V DC |
| Operating voltage | ATL-ORC-UC90-D24 | 24 V DC |
| Heat output | ATL-ORC-UC90-D12 | 1.8-9.1 kW |
| Heat output | ATL-ORC-UC90-D24 | Up to 9.1 kW |
| Fuel consumption | ATL-ORC-UC90-D12 | 0.19-1.10 L/h |
| Electrical power during operation | ATL-ORC-UC90-D12 | 37-90 W |
| Dimensions | ATL-ORC-UC90-D12 | 355 × 135 × 218 mm |
| Weight | ATL-ORC-UC90-D12 | Catalogue value: 2.6 kg |
| Temperature setting | ATL-ORC-UC90-D12 | Catalogue value: 5-35 °C |
| Temperature setting | ATL-ORC-UC90-D24 | Depending on variant |
| Application | ATL-ORC-UC90-D12 | Depending on variant |
| Application | ATL-ORC-UC90-D24 | Cooling circuit / antifreeze |
For unpublished values, use the supplied variant's nameplate and data sheet: starting current, fastening torque, pressure, pump flow and protection devices cannot be inferred from power.
03 Recommended applications and output selection
| Indicative engine displacement | 2,5 à 5 L |
|---|---|
| Coolant circuit | Record the vehicle's actual capacity and size for target temperature, available time, circulation and heat losses. |
Engine-displacement ranges are selection guides. They do not establish a circuit-volume limit. Use the vehicle-specified antifreeze mixture and a suitable pump.
04 UC9000 family burner assembly
Drawing callouts: identify components before service. A sectional view shows operation; it does not define a disassembly sequence. Check the unit revision before ordering any part.
05 Step-by-step installation
STEP 1 - Mount the heater
Provide an accessible rigid support. Identify coolant inlet and outlet on the unit and leave clearance for the burner, pump and connections.
STEP 2 - Create the hydraulic circuit
Connect to the closed antifreeze circuit. Follow circulation direction and avoid restrictions and high points trapping air. Install the pump suitable for the circuit; separate engine coolant from drinking water.
Mounting positions Metering pump
STEP 3 - Fill and bleed
With the engine cold, fill with the vehicle-specified coolant. Open the necessary valves, bleed the heater and pump, then check level and leak tightness. Never start dry.
ACTION DETAIL - schematic
Insert both tubes until they meet.
Detail: no air pocket between tubes.
STEP 4 - Connect combustion circuits
Install combustion intake and exhaust outside the cabin. For UC5000/UC9000 use the matched metering pump. For larger units follow the supplied burner's architecture: do not replace the circuit with a small metering pump.
STEP 5 - Check electrical supply and heating
Test power under load and circulation. Measure supply/return temperatures. Check the cabin-fan control if fitted. Complete a full shutdown and recheck the level when cold.
06 Electrical connections
DC battery Fuse holder ECU / unit UC9000
+ protected near the battery; dedicated - return
Compatible controller Signal harness
Schematic. Pins, rating and voltage: use the supplied harness.
Maintain power during cooling. Normal shutdown uses the controller; do not install a switch that interrupts the cycle. Protect cables and connections against water, abrasion and heat.
Circuit detail for the illustrated family. Drawing labels identify components; check connectors, voltage and options on the supplied harness. A mains connection cannot be inferred from nominal power alone.
07 Initial commissioning
| Check | Result to verify |
|---|---|
| Rating plate and controller | SKU, voltage, fuel and connectors match |
| Mounting | Mountings, clearances, ducts and outlets checked |
| Fluid circuit | Filled and bled; no leaks |
| Supply under load | Voltage measured during starting |
| Complete cycle | Ignition, operation, setpoint and shutdown/cooling tested |
| Delivery | Rating-plate photo, measurements, date and installer recorded |
08 Operation and controls
The coolant heating setpoint differs from ambient temperature. Set the duration and program on the compatible circuit controller; check circulation and battery charge before automatic start.
| Situation | Action |
|---|---|
| Before starting | When cold, check level and antifreeze protection. Ensure required valves are open and the circuit is filled and bled. Do not start with an empty or frozen circuit. Never open a hot pressurized circuit cap. |
| Engine preheating | Program time only after an initial supervised test. Start with the correct coolant-heater controller. Displayed room temperature does not necessarily represent the coolant setpoint. Check circulation, leaks and gradual temperature rise. |
| Cabin heating | If a heat exchanger and vehicle fan controller are installed, check their operation separately. Cabin heating consumes some heat output and battery power; allow a longer preheating time than with coolant alone. |
| Shutdown / circulation fault | Stop normally with the controller; maintain power during purging and cooling. If overheating occurs or hoses remain abnormally cold, allow cooling and have the level, air bleeding, valves, restrictions and pump checked before restarting. |
09 Maintenance and winterization
| When | Work |
|---|---|
| Before use | Check fuel, battery, ducts, outlets, connections and absence of leaks. |
| After transport | Inspect mountings, cables, ducts and exposed components. |
| Before the season | Supervised test; full inspection of combustion and protective devices. |
| Engine circuit | Check cold level, antifreeze protection, bleeding and circulation. |
| After repair | Suitable seals, leak test, complete cycle and measurements recorded. |
Before use and after travel, inspect ducts, supports, openings, fuel lines and accessible connections. Once cool, remove external debris without directing water into the intake or flue.
Before the season and after storage, have the installation, battery, protection, tightness and combustion checked. Hour-based intervals, exercise-run duration and component life remain to be confirmed for the exact model and revision.
The user may keep access clear and clean cold surfaces using material-appropriate methods. Burner, exchanger, pump, sensor and ECU removal is qualified service work. Do not adjust fuel delivery or thermal protection.
After repair, require leak checks and a full cycle. Record date, hours, symptom, code, part SKUs and technician. Confirm applicable warranty terms with ATLOSON; other warranty policies are not transferred.
10 Troubleshooting and fault codes
| Symptom | Action |
|---|---|
| Display off | Check the permitted power supply, visible connection and identified protection device; a fuse that blows again requires professional diagnosis. |
| No ignition / flameout | Record the code and check fuel level and visible obstructions. Do not repeat starting or priming attempts; have fuel dosing and combustion checked. |
| Overheating / low heat output | Keep air passages clear. On a coolant circuit, allow cooling before checking the level; have air bleeding, circulation and pump checked. Do not bypass the sensor. |
| Smoke / odor / leak | Stop using the system and have it inspected before returning it to service. Do not tighten or repair a hot pipe. |
| Communication / remote control | Record the message and version. Have harness and protocol confirmed. For GSM, check the module and network availability with the installer. |
Record the exact code before clearing it. Stop and allow cooling, check the power supply under load, then ducts and the fluid circuit. Correct the cause before a supervised test. A repeated fault requires workshop service.
11 Fault-code table - COOLANT
Table for the controller/ECU of this family. The same number may have a different meaning on another revision.
| Code | Meaning |
|---|---|
| 00 / B0 | Missing or lost communication |
| 10 | Voltage too high |
| 11 | Voltage too low |
| 12 / 14 / 15 / 17 | Overheat or abnormal temperature by code |
| 13 / 50 | Ignition failure / lockout by code |
| 20 / 21 / 22 | Glow plug / circuit / version |
| 30 / 31 / 32 / 33 / 84 / 85 / 86 | Blower: circuit, speed or start |
| 38 / 39 | Auxiliary output/equipment circuit |
| 41 / 42 | Circulation pump circuit |
| 45 / 46 | Auxiliary output/equipment circuit |
| 47 / 48 | Metering pump circuit |
| 51 / 52 / 55 / 64 / 65 | Flame detection / sensor circuit |
| 60 / 61 / 62 / 71 / 72 | Temperature sensor / circuit / limit |
| 91 / 99 | ECU / memory |
| A9 | Abnormal power interruption |
| AA / AB / AC / AD / AE / AF | Self-test failure by circuit |
| D3 | Maintenance requested |
| E0 / E1 / E2 / E3 | Ignition / glow / flame monitoring |
| EE | Unidentified fault |
12 Parts, kits and purchasing
Order by part number and variant. Drawing callouts are not SKUs. Check voltage, fuel and connector before replacement. A complete-system reference is not a maintenance kit.
| Reference / purchase | Catalogue description |
|---|---|
| AT10355 | Heater non-plateau to plateau adapter cable |
| AT104897 | Fuel Tank, 10L, 304 SS-2 |
| AT104898 | Fuel Tank, 10L, 304 SS |
| AT10566 | Stainless Steel Fuel Tank 10L Gasoline Storage for Parking Heater |
| AT1146 | FUEL TANK 10, PLASTIK |
| AT1158 | Fuel pump 12V |
| AT1159 | Fuel pump 24V |
| AT1160 | Fuel pump damper |
| AT1161 | Fuel pump support |
| AT1165 | Bolt M6×10mm |
| AT1166 | Nut M6 |
| AT1167 | Flat washer 6mm*12mm |
| AT1168 | Split lock washer, M6 |
| Reference / purchase | Catalogue description |
|---|---|
| AT1169 | Fuel filter |
| AT1170 | Fuel line φ5×2.0mm L1m |
| AT1171 | Fuel line φ4mm×φ1.5mm L6m, clear |
| AT1172 | Fuel line coupling 3.5*9.5*40mm |
| AT1173 | Fuel line coupling 4.1*10.5*40mm |
| AT1174 | Fuel line clamp φ8-10mm |
| AT1175 | Fuel line clamp φ9-11mm |
| AT1176 | Coolant hose φ17*26mm CR01-5A(EPDM) |
| AT1177 | Coolant hose clamp φ20-32mm |
| AT1178 | Coolant hose coupling φ20mm, L55mm |
| AT1179 | Coolant hose reducing coupling φ18*20mm, L60mm |
| AT1180 | Air inlet pipe 20.5 x 24mm x L900mm |
| AT1181 | Air inlet pipe strap |
| AT1182 | Air inlet pipe clamp φ16-25mm |
| AT1187 | Rubber shock absorbers 5*20*4mm |
| AT1188 | Self-drilling and self-tapping screw ST5.5×30 |
| AT1189 | Fuel pickup tube |
| AT1191 | 4-port bypass valve |
| AT119101 | Air Intake Silencer |
| AT119102 | Elbow Connector, 90 |
| AT119105 | Fuel Pump Connector |
| AT119108 | Fuse Base |
| AT119109 | Fuse Base 2 |
| AT1192 | Digital control switch, GSM compatible |
| AT1193 | Check valve |
| AT15001 | Diagnostics USB Cable |
| AT9121 | UC9000 - MAINTENANCE KIT 12V DIESEL |
| AT9122 | UC9000 - Heater Only 12v Diesel |
| AT9123 | UC9000 - Heater Only 24v Diesel |
| AT9124 | Burner Housing |
| AT9125 | Heater Housing |
| AT9126 | Heater Inner Housing |
| AT9127 | Rubber-Lined Clamp |
| AT9128 | Fan Cover |
| AT9129 | Combustion Tube Gasket |
| AT9130 | Flame Sensor |
| AT9131 | Glow Plug 24V |
| AT9132 | Glow Plug 12V |
| Reference / purchase | Catalogue description |
|---|---|
| AT9133 | Air Intake Cover |
| AT9134 | Combustion Tube |
| AT9135 | Wiring Harness Retaining Plate |
| AT9136 | Coolant Pump 12V - UC9000 |
| AT9137 | Coolant Pump 24V - UC9000 |
| AT9138 | 9 kW Water Pump O-Ring |
| AT9139 | Coolant Temperature Sensor |
| AT9140 | Overheat Protection Assembly |
| AT9141 | Burner UC9000 |
| AT9142 | Fuel Inlet Line |
| AT9143 | Blower Assembly 12V - UC9000 |
| AT9144 | Blower Assembly 24V - UC9000 |
| AT9145 | Single-Ear Stepless Clamp |
| AT9146 | Locking Connector Ring |
| AT9147 | O-Ring Seal - EPDM O-Ring, 105 × 2.65 cm |
| AT9148 | 24V SLM Relay |
| AT9149 | 5A Blade Fuse |
| AT9150 | UC9000 - ECU assembly 12V |
| AT9151 | UC9000 - ECU assembly 24V |
| AT9152 | Heater Relay Wiring Harness UC9000 |
| AT9153 | Exhaust pipe |
| AT9155 | Exhaust pipe clamp |
| AT9156 | Exhaust Muffle UC9000 |
| AT9162 | Fuel Filter 2017 |
| AT9163 | Mount Plate UC9000 |
| ATL9001 | UC9000 Heater Kit, Coolant Heater, 9kw, 12v, Diesel, Controller LCD - BT |
| ATL9003 | UC9000 Heater Kit, Coolant Heater, 9kw, 24v, Diesel, Controller LCD - BT |
Records and support
Date / hours: __________________ Work / parts: __________________
Keep the invoice, SKU, serial number and history. For assistance, provide a nameplate photo, code and symptom. ATLOSON support