NERAL BD6000 Installation & Operation Manual
NERAL BD6000 · English · 13 PDF pages
Supplied V5 edition, marked draft for approval. Unresolved values remain ‘To be confirmed’. Check the delivered unit’s SKU, fuel, voltage, serial number and controller revision; references are not proof of compatibility.
Current ATLOSON warranty excludes burners. Original documents may describe earlier terms; consult the current warranty on the product page.
Complete manual downloads
- Download NERAL BD6000 Installation & Operation Manual – English PDFV5 · 13 pages · English
- Télécharger le manuel d’installation et d’utilisation NERAL BD6000 – Français PDFV5 · 13 pages · Français
- Descargar el manual de instalación y funcionamiento NERAL BD6000 – Español PDFV5 · 13 pages · Español
- NERAL BD6000 Installations- und Bedienungsanleitung herunterladen – Deutsch PDFV5 · 13 pages · Deutsch
- Скачать руководство по установке и эксплуатации NERAL BD6000 – Русский PDFV5 · 13 pages · Русский
Current catalogue configurations
These links show the current catalogue identifiers. Reference SKUs in the supplied V5 manual may differ; confirm the delivered unit before installation or ordering.
| Configuration | Power | Voltage | Fuel |
|---|---|---|---|
| ATL7001 · Complete system | 6 kW | 12V / 120V | Diesel / Electric |
| ATL7002 · Complete system | 6 kW | 12V / 120V | Gasoline / Electric |
| ATL7003 · Complete system | 6 kW | 12V / 120V | Propane / Electric |
01 Identification, safety and use
This manual accompanies model NERAL BD6000. Record SKU, serial number, voltage, fuel and revision before installation. Accessories, functions and protective devices depend on the supplied variant.
Cabin heating and domestic hot-water preparation in a recreational vehicle or converted van. Separate cold/hot-water, warm-air and combustion circuits.
| SKU | Fuel | Voltage |
|---|---|---|
| ATL-NER-BD6-D | Diesel + Electric | 12V + 120V |
| ATL-NER-BD6-G | Gasoline + Electric | 12V + 120V |
| ATL-NER-BD6-P | Propane + Electric | 12V + 120V |
Carbon monoxide: combustion gases must remain outside occupied spaces. Do not operate in a garage or other enclosed location. Keep intakes and flue outlets clear, especially after snow, mud or travel.
Fuel smell, abnormal smoke, leakage or a CO alarm: stop use, move occupants away and have the installation inspected. Do not restart to conceal a fault. Contact emergency services if there is immediate danger.
Fire and burns: keep combustible materials away from the appliance, hot ducts and exhaust. Do not use the service compartment for storage. Allow cooling before inspection and keep children away from hot surfaces.
Power: use the nameplate voltage. Never increase a fuse rating or bypass protection. For a normal stop, allow the controlled cooling cycle to finish before disconnecting power.
Stop before refuelling. Fuel, combustion, gas and mains work require a qualified professional. Install and maintain a CO detector suitable for the application according to its own instructions.
Combi heating: identify the warm-air circuit separately from the domestic-water tank. Confirm pump, pressure, relief valve, draining and frost protection. Do not energise a water element dry. Diesel, gasoline and propane versions each require their own supply. Mains power needs protection and earthing according to the approved design.
02 Variant specifications
| Common specification | Value |
|---|---|
| Operating voltage | 12V + 120V |
| Water tank | 10 L stainless-steel tank (catalogue) |
| Vehicle power supply | 12 V nominal |
| Mains supply | 120 V configuration |
| Dimensions | 510 × 450 × 300 mm |
| Weight | 15.6 kg |
Differences between variants
| Specification | SKU | Value |
|---|---|---|
| Fuel | ATL-NER-BD6-D | Diesel + Electric |
| Fuel | ATL-NER-BD6-G | Gasoline |
| Fuel | ATL-NER-BD6-P | Propane + Electric |
| Heat output class | ATL-NER-BD6-D | Catalogue value: Up to 6 kW |
| Heat output class | ATL-NER-BD6-G / ATL-NER-BD6-P | Up to 6 kW |
| Maximum airflow | ATL-NER-BD6-D / ATL-NER-BD6-P | 287 m³/h (catalogue value) |
| Maximum airflow | ATL-NER-BD6-G | Depending on variant |
| Specification | SKU | Value |
|---|---|---|
| Operating temperature | ATL-NER-BD6-D / ATL-NER-BD6-P | -25 to +40 °C |
| Operating temperature | ATL-NER-BD6-G | Depending on variant |
| Ingress protection rating | ATL-NER-BD6-D / ATL-NER-BD6-P | IP21 (catalogue value) |
| Ingress protection rating | ATL-NER-BD6-G | Depending on variant |
For unpublished values, use the supplied variant's nameplate and data sheet: starting current, fastening torque, pressure, pump flow and protection devices cannot be inferred from power.
03 Recommended applications and output selection
Select according to insulation, outdoor temperature, heated volume and air exchange. For domestic water: water demand, pressure and frost protection. Engine displacement and engine coolant volume are not applicable to this unit.
04 BD6000 propane version exploded view
Drawing callouts: identify components before service. A sectional view shows operation; it does not define a disassembly sequence. Check the unit revision before ordering any part.
05 Step-by-step installation
STEP 1 - Prepare the compartment
Secure the base and maintain access to the drain, connections and electronics. Keep the return-air inlet clear and distribute heating outlets.
STEP 2 - Mount the combustion terminal
Use the terminal and ducts for the supplied variant. Observe the TOP marking and intake/exhaust connections. Check every clamp and leak tightness before closing the compartment.
Terminal: propane version Unobstructed return air
STEP 3 - Connect domestic water
Connect cold water and hot outlet without mechanical stress on fittings. Install the safety valve, drain and downward outdoor discharge. Fill with a hot-water tap open until air is expelled.
ACTION DETAIL - schematic
Tank connection
Support the tube. Insert as specified for the supplied connector.
Check retention and sealing.
STEP 4 - Connect the energy supply
Diesel/gasoline: matched circuit and pump. Propane: regulator and line according to the nameplate; leak test by a competent person. Mains: voltage, earth and protection devices for the actual supplied version.
Duct and clamp Propane connection
STEP 5 - Commission
Test air, water and then combined mode. Test available energy sources separately. Check hot outlets, domestic-water leak tightness and draining. Do not activate heating elements with an empty tank.
06 Electrical connections
DC battery Fuse holder ECU / unit BD6000
+ protected near the battery; dedicated - return
Compatible controller Signal harness
Schematic. Pins, rating and voltage: use the supplied harness.
Mains: separate circuit with grounding and protective devices matched to the rating plate.
Maintain power during cooling. Normal shutdown uses the controller; do not install a switch that interrupts the cycle. Protect cables and connections against water, abrasion and heat.
Circuit detail for the illustrated family. Drawing labels identify components; check connectors, voltage and options on the supplied harness. A mains connection cannot be inferred from nominal power alone.
The detailed diagram above shows the propane branch. The diesel branch uses its diesel-burner harness; do not connect a metering pump to a gas-valve output.
07 Initial commissioning
| Check | Result to verify |
|---|---|
| Rating plate and controller | SKU, voltage, fuel and connectors match |
| Mounting | Mountings, clearances, ducts and outlets checked |
| Fluid circuit | Filled and bled; no leaks |
| Supply under load | Voltage measured during starting |
| Complete cycle | Ignition, operation, setpoint and shutdown/cooling tested |
| Delivery | Rating-plate photo, measurements, date and installer recorded |
08 Operation and controls
Fill the domestic-water tank before water heating. Select an available mode: water, air or combined according to unit; fuel, mains or mixed according to variant. A setpoint does not guarantee immediate tap-water temperature: scalding hazard.
| Situation | Action |
|---|---|
| Fill the domestic-water circuit | Close the drain, open a hot-water tap and run the water pump until water flows continuously without air. Check connections. Do not activate water heating or heating elements with an empty tank. |
| Mains / propane | Confirm the 120 V version and protection devices before connection. Current or power from a 230 V version does not apply to the 120 V version. For propane, have a competent person check the regulator, pressure and leak tightness. |
| Winterization | Switch off heat sources, allow cooling, stop the water pump and fully drain the tank and pipes according to their layout. Open taps to admit air. Check that no water remains at low points; merely stopping the heater does not protect against freezing. |
09 Maintenance and winterization
| When | Work |
|---|---|
| Before use | Check fuel, battery, ducts, outlets, connections and absence of leaks. |
| After transport | Inspect mountings, cables, ducts and exposed components. |
| Before the season | Supervised test; full inspection of combustion and protective devices. |
| Domestic water | Check valve and drain; drain before frost or storage. |
| After repair | Suitable seals, leak test, complete cycle and measurements recorded. |
Before use and after travel, inspect ducts, supports, openings, fuel lines and accessible connections. Once cool, remove external debris without directing water into the intake or flue.
Before the season and after storage, have the installation, battery, protection, tightness and combustion checked. Hour-based intervals, exercise-run duration and component life remain to be confirmed for the exact model and revision.
The user may keep access clear and clean cold surfaces using material-appropriate methods. Burner, exchanger, pump, sensor and ECU removal is qualified service work. Do not adjust fuel delivery or thermal protection.
After repair, require leak checks and a full cycle. Record date, hours, symptom, code, part SKUs and technician. Confirm applicable warranty terms with ATLOSON; other warranty policies are not transferred.
Winter storage: stop, allow cooling, switch off the water pump and open taps and drains. Check that the tank and low points actually drain. Before restarting, fill and bleed; never heat an empty tank.
10 Troubleshooting and fault codes
| Symptom | Action |
|---|---|
| Display off | Check the permitted power supply, visible connection and identified protection device; a fuse that blows again requires professional diagnosis. |
| No ignition / flameout | Record the code and check fuel level and visible obstructions. Do not repeat starting or priming attempts; have fuel dosing and combustion checked. |
| Overheating / low heat output | Keep air passages clear. On a coolant circuit, allow cooling before checking the level; have air bleeding, circulation and pump checked. Do not bypass the sensor. |
| Smoke / odor / leak | Stop using the system and have it inspected before returning it to service. Do not tighten or repair a hot pipe. |
| Communication / remote control | Record the message and version. Have harness and protocol confirmed. For GSM, check the module and network availability with the installer. |
Record the exact code before clearing it. Stop and allow cooling, check the power supply under load, then ducts and the fluid circuit. Correct the cause before a supervised test. A repeated fault requires workshop service.
11 Fault-code table - family controller
Use only with a controller displaying this set of codes. Gas, pump and heating-element outputs depend on the variant.
| Code | Action |
|---|---|
| 10 / 11 | High / low voltage |
| 21 / 22 | Air-outlet sensor open circuit / short circuit |
| 23 / 24 | Water sensor open circuit / short circuit |
| 25 / 26 | Ambient sensor open circuit / short circuit |
| 27 / 28 | Combustion sensor open circuit / short circuit |
| 31 / 32 / 33 | Ignition / combustion / flame sensor |
| 41 / 42 / 43 / 44 / 45 | Air/water overheating, depending on code |
| 51 | Panel / ECU communication |
| 61 / 62 | Metering pump open circuit / short circuit |
| 63 / 65 | Glow plug open circuit / glow plug control |
| 71 / 72 | Gas valve / gas control |
| 81 / 82 / 83 | Combustion fan: open circuit / starting / speed |
| 84 / 85 / 86 | Heating fan: open circuit / starting / speed |
| 91 / 92 / 93 / 94 | High-voltage ignition / gas valve: propane reference |
| 110 | Window / interlock |
| 120 | Low-voltage alarm |
| 169 | CPU reset after power interruption |
| 220 | No mains supply |
12 Parts, kits and purchasing
Order by part number and variant. Drawing callouts are not SKUs. Check voltage, fuel and connector before replacement. A complete-system reference is not a maintenance kit.
| Reference / purchase | Catalogue description |
|---|---|
| AT0003 | Fuel Line Adapter 90' 7.5mm to 4.5mm |
| AT103516 | TEMPERATURE EXTERNE SENSOR |
| AT1048 | Fuel line clamp φ12-14mm |
| AT104897 | Fuel Tank, 10L, 304 SS-2 |
| AT1049 | Air duct clamp |
| AT1050 | Air diffuser (grille) |
| AT10566 | Stainless Steel Fuel Tank 10L Gasoline Storage for Parking Heater |
| AT10569 | T-Joint, 60 mm |
| AT1057 | Self-drilling self-tapping screw ST5.5×25 |
| AT10570 | Air Duct Connector, 60-90 mm |
| AT10571 | Air Duct Elbow Connector, 60 mm |
| AT10572 | Air Duct Straight Connector, 60 mm |
| AT10573 | Air Duct Y, 60 mm |
| Reference / purchase | Catalogue description |
|---|---|
| AT10574 | Air Ducting, 60 mm, 5 m Length |
| AT10575 | Air Outlet with Adjustable Louvers, 60 mm |
| AT1146 | FUEL TANK 10, PLASTIK |
| AT1158 | Fuel pump 12V |
| AT1160 | Fuel pump damper |
| AT1161 | Fuel pump support |
| AT1166 | Nut M6 |
| AT1167 | Flat washer 6mm*12mm |
| AT1170 | Fuel line φ5×2.0mm L1m |
| AT1171 | Fuel line φ4mm×φ1.5mm L6m, clear |
| AT1172 | Fuel line coupling 3.5*9.5*40mm |
| AT1173 | Fuel line coupling 4.1*10.5*40mm |
| AT1174 | Fuel line clamp φ8-10mm |
| AT1175 | Fuel line clamp φ9-11mm |
| AT1189 | Fuel pickup tube |
| AT119105 | Fuel Pump Connector |
| AT504898 | Fuel Tank, 25L, SS |
| AT50575 | Air Outlet with Adjustable Louvers, 90 mm |
| AT6001 | NERAL - BD Series Diagnostics USB Cable |
| AT60031 | BD6000 MAINTENANCE KIT 12V DIESEL |
| AT60041 | BD6000 MAINTENANCE KIT 12V GASOLINE |
| AT6008 | Process Air Blower Motor |
| AT6009 | Combustion Fan O-ring |
| AT6010 | Water Tank Seal |
| AT6013 | Intake & Exhaust Bulkhead Fitting |
| AT6014 | Process Air Impeller |
| AT6015 | Atomizing Screen |
| AT6016 | Combustion Air Cowl |
| AT6017 | Combustion Air Intake Pipe |
| AT6018 | 60 mm Air Outlet Vent |
| AT6019 | 60 mm Hot Air Duct, 5 m |
| AT6020 | 60 mm Hot Air Duct, 1 m |
| AT6021 | NERAL Control Panel Digital |
| AT6022 | Thermostat Extension Cable |
| AT6026 | Sealing Rubber Spacer |
| AT6027 | Front Housing Cover |
| AT6028 | Combustion Blower Cover |
| AT6029 | Aluminum Heat Shield |
| Reference / purchase | Catalogue description |
|---|---|
| AT6030 | Air Intake Grille |
| AT6031 | Water Temp Sensor |
| AT6032 | 12V Supply Cable |
| AT6033 | 220V AC Power Cable |
| AT6034 | 7 m Fuel Pump Extension Harness |
| AT6035 | Pressure Safety Valve, 1/2" NPT |
| AT6036 | Serrated Lock Washer |
| AT6037 | Nut |
| AT6038 | M4 Allen Screw |
| AT6039 | NERAL Series Fitting Kit |
| AT6040 | Dual LPG Valve |
| AT6041 | Socket Head Cap Screw |
| AT6042 | NERAL 1/2" NPT Compression Adapter |
| AT6043 | Fuel Line Bracket Gasket |
| AT6044 | 1/2" NPT Freeze Protection Valve |
| AT6045 | G-Thread Pressure Relief Valve |
| AT6046 | G-Thread Freeze Protection Valve |
| AT6047 | Manual Pressure Relief Valve |
| AT6048 | Heat Sink Base |
| AT6049 | Thermal Transfer Plate |
| AT6050 | U-Shaped Heating Element 900W/ 230V |
| AT6051 | U-Shaped Heating Element 900W/ 110V |
| AT6052 | Combustion Blower PIN |
| AT6053 | Combustion Blower Assembly |
| AT6054 | Combustion Blower Wheel |
| AT6055 | Combustion Blower Mounting Bracket |
| AT6056 | Air Baffle Plate |
| AT6057 | Air Guide Plate |
| AT6058 | Burner Mounting Base |
| AT6059 | Heating Blower Cover |
| AT6060 | Combustion Tube Mount |
| AT6061 | Burner Baffle Plate |
| AT6062 | H-Type Ignition Electrode |
| AT6063 | Mesh Burner Cover |
| AT6064 | Burner Cover Plate |
| AT6065 | High-Voltage Ignition Coil |
| AT6066 | Combustion Tube Assembly |
| AT6067 | Controller Housing Cover |
| Reference / purchase | Catalogue description |
|---|---|
| AT6068 | Controller Mounting Bracket |
| AT6069 | R-Type Cable Clamp |
| AT6070 | Electric Heater Control Cable |
| AT6071 | Coolant Overheat Switch Gasket |
| AT6072 | Coolant Temperature Sensor Gasket |
| AT6073 | Overheat Switch Retaining Clip |
| AT6074 | Intake Air Temperature Sensor |
| AT6075 | Plate Sealing Compound |
| AT6076 | Insulating Washer |
| AT6077 | NERAL BD Water Tank |
| AT6078 | Snap-Action Temperature Limiter |
| AT6079 | Tank Overheat Switch Gasket |
| AT6080 | Safety Switch Wiring Harness |
| AT6081 | Rear Housing Cover |
| AT6082 | Air Outlet Cover |
| AT6083 | Hot Air Combination Sensor |
| AT6084 | Protective Insulation Sheet |
| AT6085 | Aluminum Heat Shield |
| AT6086 | Wiring Harness Sealant |
| AT6087 | Stainless Steel Gas Flex Hose |
| AT6088 | Intake & Exhaust Port Assembly - White |
| AT6089 | Intake & Exhaust Port Assembly - Black |
| AT6090 | Precision Steel Tube |
| AT6091 | Straight Adapter Fitting |
| AT6092 | Intake & Exhaust Port Cover - White |
| AT6093 | Intake & Exhaust Port Cover - Black |
| AT6094 | Hose Clamp |
| AT6095 | Air Intake Pipe Retaining Clip |
| AT6096 | Exhaust Pipe |
| AT6097 | Tee Fitting |
| AT6098 | Corrugated Tube Retaining Clip |
| AT6099 | Tank Air Vent Valve |
| AT6100 | Cooling Fan |
| AT6101 | Dual Gas Safety Valve |
| AT6102 | Single-Line Gas Safety Valve Assembly, Ø8 mm |
| AT6103 | Gas Safety Switch |
| AT6104 | Gas Safety Switch |
| AT6105 | Air Pump Assembly |
| Reference / purchase | Catalogue description |
|---|---|
| AT6106 | Dual-Line Gas Filter |
| AT6107 | Gas Cylinder Connection Hose |
| AT6108 | German-Standard LPG Cylinder Connection Hose |
| AT6109 | Gas Safety Switch Connection Hose |
| AT6110 | Flame sensor |
| AT6111 | Fuse 20A/250V 5*20 |
| AT6112 | Combustion Chamber Assembly |
| AT6113 | Thermocouple |
| AT7005 | BD6000 Heater Only Diesel |
| AT7006 | BD6000 Heater Only Gasoline |
| AT7007 | BD6000 Heater Only Propane |
| AT7023 | BD6000 12V Diesel Control Unit |
| AT7024 | BD6000 12V Gasoline Control Unit |
| AT7025 | BD6000 12V Propane Control Unit |
| ATL7001 | BD6000 Heater Kit, Dual Air/Water, 6kw, 12V/120V, Diesel, Controller Digital - BT |
| ATL7002 | BD6000 Heater Kit, Dual Air/Water, 6kw, 12V/120V, Gasoline, Controller Digital - BT |
| ATL7003 | BD6000 Heater Kit, Dual Air/Water, 6kw, 12V/120V, Propane, Controller Digital - BT |
| ATM001007 | NERAL - BD6000 Instruction Manual |